Maintenance-Object Repair Procedures
Table 8-356. Test #61 Hybrid Line Audits Test — Continued
Error
Test
Code
Result
Description / Recommendation
1004
ABORT
The port was seized by a valid call during the test. The test has been aborted.
1. Use the display port UUCSSpp command to determine the station
2. Retry the command at 1-minute intervals up to 5 times.
1392
ABORT
This port is currently a TTI port and the test will not execute on it.
1. Verify that the port is a TTI port using either the display port command
2. If either list config or display port indicate that the port is not a TTI port,
2000
ABORT
Response to the test request was not received within the allowable time period.
FAIL
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS
Hybrid Line Audits test passed.
1. Although this test never actually returns a FAIL result (except for the
2. If these errors appear in the Error Log, or if user complaints still exist,
0
NO
The test could not relate the internal ID to the port (no board). This could be
BOARD
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the list
2. If the board was found to be correctly inserted in step 1, issue the busyout
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the linkage
8-922
Issue 1 May 2002
extension number of the port. Use the status station command to
determine the service state of the port. If the port is in use, wait until it is
idle before testing.
(the display shows that the port is a TTI port) or the list config command
(the display shows a
t
for the port).
escalate the problem. If both commands indicate that the port is a TTI port,
the abort is correct, and no action is necessary.
previous Internal system error), it can enter Error Types 257 and 513 into
the Error Log. To check for problems that don't show up in the test result,
look for these error types in the Error Log.
investigate by using other circuit pack tests, and by examining the station,
wiring, and connections.
config command, and resolve any problems that are found.
board command.
between the internal ID and the port. If this is not the case, dispatch to
check to ensure that there is a valid board inserted.
Continued on next page