Maintenance-Object Repair Procedures
Expansion Interface Control Channel Test (#316)
This test is nondestructive. If an EI circuit pack is a standby EI circuit pack (amber
LED off) or if the EI is active in the PN (amber LED on), this test queries the EI
circuit pack for its circuit pack type and vintage information. If the EI circuit pack is
an active EI circuit pack in the PN (amber LED on long off short) the Expansion
Interface Control Channel test checks to see if the EI circuit pack can
communicate with other circuit packs in the PN using the PN TDM bus.
Table 8-308. Test #316 Expansion Interface Control Channel Test
Error
Test
Code
Result
Description / Recommendation
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this test.
2500
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
Any
FAIL
The EI circuit pack responded incorrectly or if it is the PN active EI circuit pack,
it could not talk to PN circuit packs.
1. If the active EI circuit pack in the PN is failing and duplicated Port Network
2. Repeat the short test sequence.
3. If test continues to fail, reset the EI circuit pack via the reset board
4. If the EI circuit pack in the PN is failing, enter display errors and display
5. Repeat the short test sequence.
6. If test continues to fail, replace the circuit pack or transceiver.
PASS
The EI circuit pack did respond correctly to test. Communication from software
to the EI circuit pack is functioning.
1. Refer to other EI circuit pack tests if the link is not functioning correctly.
0
NO
No board was detected by the test.
BOARD
1. Resolve either wrong board (Error 125) or no board (Error 131) issues.
2. Check that the board is properly translated and inserted. If so, check for
3. Run the test again. If it fails, the ID chip on board may be bad. Replace
8-804
Issue 1 May 2002
Connectivity is enabled, attempt to switch to the standby PNC using the
reset PNC interchange command.
UUCSS command.
alarms, and resolve any TDM-CLK, TONE-BD, or SYNC alarms or errors.
hyperactivity (Error 1538). If hyperactive, use the reset board UUCSS
command.
the board and retest.