Avaya S8700 Maintenance Manual page 1716

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Error Log Entries and Test to Clear Values
Table 8-392. DS1 ISDN Trunk Error Log Entries
Error
Aux
Type
Data
Associated Test
1
0
0
Any
1 (a)
Any
None
15 (b)
Any
Audit and Update test
(#36)
18
0
busyout trunk
grp/mbr
19 (c)
0
None
129 (d)
None
130 (e)
None
257 (f)
Any
None
513 (g)
Any
None
769 (f)
Any
None
1025 (h)
0
None
1281
Any
Conference Circuit test
(#7)
1537
Any
NPE Crosstalk test
(#6)
1793 (i)
Any
None
3073 (j)
Any
Service State audit
(#256)
3585 (k)
Any
None
3841 (l)
Any
None
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
2.
Major or minor alarms may be downgraded to Warning alarms based on the value used in the set options
command.
Notes:
a. These Error Types indicate a disagreement between this switch and the
switch at the other end of the trunk connection with regard to the ISDN call
state of the DS1 ISDN Trunk. This switch will automatically try to recover
by clearing the call, (that is, call will be torn down). You can use the status
trunk group#/member# command to determine the state of the trunk.
8-994
Issue 1 May 2002
On/Off
Alarm Level
Board
Any
Any
WARNING
OFF
WARNING
ON
WARNING
OFF
MAJOR MINOR
ON
2
WARNING
MAJOR MINOR
ON
2
WARNING
WARNING
OFF
Test to Clear Value
test port UUCSSpp
test port UUCSSpp
release trunk grp/mbr
test port UUCSSpp
test port UUCSSpp
test port UUCSSpp
test port UUCSSpp
test port UUCSSpp
test port UUCSSpp l r 4
test port UUCSSpp l r 3
test port UUCSSpp
test port UUCSSpp
none
None
555-233-143