Table 8-157. Test #628 BRI XID — Continued
Error
Test
Code
Result
Description / Recommendation
1141
ABORT
The PKT-CTRL is out-of-service.
1. Refer to PKT-CTRL (Packet Control Circuit Pack) Maintenance
2. If step 1 does not resolve the problem, escalate to the next tier.
1187
ABORT
The circuit pack, port or station may have been busied out by a technician.
1. Look in the Error Log for Error Type 18 (busied out) for BRI-BD, BRI-PORT,
2. Make sure the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
4. If the test continues to abort, escalate the problem.
2012
ABORT
Internal system error.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
8-374
Issue 1 May 2002
documentation.
or BRI-SET.
a. If this error type is present for BRI-SET only, then release the station via
the release station.
b. If this error type is present for BRI-PORT and BRI-SET, then release
the port via release port PCSSpp command and run the test again.
c. If the error is present for BRI-BD, BRI-PORT, and BRI-SET, then
release the circuit pack via the release port PCSSpp command and
run the test again. If the error is present for BRI-SET only, then release
the circuit pack via the release port PCSSpp command and run the
test again. If the error is present for both BRI-BD and BRI-PORT, then
release the circuit pack via the release board PPCSS command and
run the test again.
NOTE:
When you release the circuit pack, you release every port associated
with it. If certain ports still need to be busied out, use the busyout port
PCSSpp command to busy them out.