Asai-Bd (Multi-Application Platform Board) - Avaya S8700 Maintenance Manual

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
ASAI-BD (Multi-Application Platform
Board)
MO's Name (in
Alarm Log)
ASAI-BD
ASAI-BD
1.
Where UU is the universal cabinet number (1–64 for ATM PNC, 1–44 for CSS PNC); C is the
carrier designation (A, B, C, D, or E); SS is the address of the slot in the carrier where the circuit
pack resides (01 to 21); and pp is the 2-digit port number (01, 02, 03, ...).
Maintenance testing of the common circuit pack is handled by on-board firmware
and server-controlled tests. Maintenance software queries the firmware for error
and alarm information, status, and test results. Firmware automatically reports
error conditions that result in server-controlled testing.
For MAPD board insertion, the switch makes an additional board query if any of
the following circuit packs are inserted:
Circuit Pack
TN754
TN556
TN800
For any of the previous initial board uplinks, the switch queries the board for
administration data as well as reporting the switch software release and the
system type.
8-144
Issue 1 May 2002
Alarm
Initial Command to
1
Level
Run
MINOR
test board UUCSS pp
WARNING
test board UUCSS pp
Vintage
49
49,
80 or greater
any
Full Name of MO
ASAI-BD
ASAI-BD
555-233-143

Advertisement

Table of Contents
loading

Table of Contents