ANN-BD (Announcement Circuit Pack)
Table 8-51. Test #212 Clock Match Inquiry Test
Error
Test
Code
Result
Description / Recommendation
2000
ABORT
Response to the test was not received within the allowable time period. If Error
Type 1538 is present in the Error Log, follow the procedure for that error.
2100
ABORT
Could not allocate the necessary system resources to run this test.
ABORT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
The ANN-BD may be defective, or the active Tone-Clock circuit in the same
EPN may be bad. Announcements recorded or played back while the clock
circuitry is not functioning properly sound distorted.
1. Enter reset board UUCSS to reset the Announcement circuit pack, and
2. If this EPN has duplicated Tone-Clocks:
!
3. If the EPN has a single Tone-Clock, replace the ANN-BD, and rerun the
!
4. If failures of this test continue to raise alarms, replace the circuit pack even
PASS
Announcement playbacks must have clear sound quality. Investigate
user-reported troubles on this circuit pack using the other circuit pack and port
tests. Refer to "ANN-PT" for descriptions of the port tests.
555-233-143
run this test again. If the test continues to fail, proceed to step 2 or 3,
whichever applies.
a. Enter status port-network 1 to determine the EPN's active TONE-BD.
b. Enter set tone-clock UUC to make the standby Tone-Clock or IPSI
circuit pack active.
c. Rerun the test. If the test passes, replace the now standby Tone-Clock
or IPSI circuit pack. If not, replace the ANN-BD circuit pack.
CAUTION:
Replacing the announcement circuit pack results in loss of integrated
announcements. See
''Essential Service
(Tone-Clock Circuit)''
for Tone-Clock replacement instructions.
test. If the test continues to fail, replace the Tone-Clock circuit pack
located in the same EPN as the ANN-BD.
CAUTION:
Replacing an unduplicated EPN Tone-Clock will cause an EPN reset with
service outage to that EPN. See
Circuit Pack'' on page
8-1666. Replacing the circuit pack causes a loss
of integrated announcements. See
page 8-120
of AN-LN-PT MO.
if the previous steps were successful.
Information''. See
''Replacing the IPSI or Tone-Clock
''Essential Service Information'' on
Continued on next page
Issue 1 May 2002
''TONE-BD