EXP-INTF (Expansion Interface Circuit Pack)
Table 8-306. Test #241 Expansion Interface 2-Way Transmission Test — Continued
Error
Test
Code
Result
Description / Recommendation
1033
ABORT
The test cannot run because either the EI board does not have a fiber link
administered to it and there is not sufficient data to run the test, or there were
no other PNs administered that had its EI board In-Service.
1. Check fiber administration to insure that there is a fiber link administered to
2. If there is a fiber administered to this EI circuit pack, then some change in
3. Test #237 and check for EXP-INTF circuit pack Error Type 1281 in the
4. If Test #237 passes, reseat the EI circuit pack. This is not destructive since
1394
ABORT
The EI circuit pack is out of service and the test cannot be run. This condition
is due to a change in the EI circuit pack's ability to communicate with the EI or
SNI circuit pack on the other end of the fiber.
1. Run Test #237, and check the Error Log for EXP-INTF Error Type 1281. If
1395
ABORT
This test cannot be run on an EI circuit pack if it is part of the B-side PNC and
duplicated PNC is not enabled.
1. If this test needs to run on this EI circuit pack, enable PNC with the change
2. Prevent the system from doing a PNC interchange by executing the set
3. Repeat this test.
1413
ABORT
This test requires the use of a Tone-Clock circuit pack in each of the PNs used
in this test. This abort code indicates that there are none of these circuit packs
located in one of the PNs.
1. Verify that there is a Tone-Clock circuit pack in the PN where the EI circuit
2. In a Direct Connect configuration, verify that there is a Tone-Clock circuit
3. In a Center Stage Switch configuration, verify that there is at least one
555-233-143
this EI circuit pack.
the status of the ability of the EI circuit pack in the other PNs to
communicate with the EI or SNI circuit pack on the other end of its fiber has
occurred.
Error Log for the EI circuit packs in these other PNs. If Error Type 1281 is
present and/or Test #237 does not pass, see repair procedures for Test
#237, in
Table 8-303 on page
the circuit pack cannot be serving as the Expansion Archangel if it is not in
service.
Error Type 1281 is present or if Test #237 fails, see repair procedures for
Test #237, in
Table 8-303 on page
system-parameters duplication command.
PNC lock command.
pack under test resides.
pack in the PN where the neighbor EIEI circuit pack circuit pack resides.
other PN, besides the PN where the EI circuit pack under test resides, with
a Tone-Clock circuit pack.
8-787.
8-787.
Continued on next page
Issue 1 May 2002
8-795