Maintenance-Object Repair Procedures
Table 8-311. Test #224 Expansion Interface Test — Continued
Error
Test
Code
Result
Description / Recommendation
5016,
FAIL
Initialization failure: the EI circuit pack reset successfully and restarted
5017,
execution, but the EI circuit pack detected communication errors during
5018,
hardware initialization. The nature of the failure may prevent the EI circuit pack
5019,
from communicating with its neighbor EI circuit pack on the opposite end of the
5032,
fiber. The fault itself may be either on the EI circuit pack or on the lightwave
5033,
transceiver.
5048,
1. If every other test on this EI circuit pack is passing and no other errors
5064,
5080,
5096,
2. If some tests on this EI circuit pack are failing or other errors have been
5112
PASS
The EI was successfully reset, and it restarted execution. It also passed all of
its initialization tests and detected a lightwave transceiver. Remove the EI
circuit pack from the busyout state by using the release board PCSS
command.
1. Execute test board PCSS short command. Refer to errors for each test.
0
NO
No board was detected by the test.
BOARD
1. Resolve either wrong board (Error 125) or no board (Error 131) issues.
2. Check that the board is properly translated and inserted. If so, check for
3. Run the test again. If it fails, the ID chip on board may be bad. Replace
8-820
Issue 1 May 2002
have been logged against this circuit pack, replacement of the lightwave
transceiver or the circuit pack is recommended, but not critical.
logged against this circuit pack, replace the lightwave transceiver and/or
the EI circuit pack.
hyperactivity (Error 1538). If hyperactive, use the reset board UUCSS
command.
the board and retest.
Continued on next page