Table 8-137. Test #33 Looparound and Conference Test — Continued
Error
Test
Code
Result
Description / Recommendation
129
FAIL
The reflective 404-Hz tone test failed, no transmission was detected to or from
the port. The problem may be off-board.
131
FAIL
The reflective 1004-Hz tone test failed. No transmission was detected to or
from the port. The problem may be off-board.
133
FAIL
The reflective 2804-Hz tone test failed. No transmission was detected to or
from the port. The problem may be off-board.
1. To make sure the problem is on-board, disconnect the port from the
2. If the test fails, replace the circuit pack. Otherwise, if the test passed after
PASS
Looparound and Conference test is successful. This port is functioning
properly.
8-316
Issue 1 May 2002
auxiliary equipment and retry test.
disconnecting the port from the auxiliary equipment, the problem is
off-board. Check the wiring and connections to the auxiliary equipment
and retry the test after reconnecting the port to the auxiliary equipment. If
the test fails, check the auxiliary equipment. See the preceding procedure
for a failure with Error Code 7.
NOTE:
If the Looparound and Conference test fails for every port on a circuit
pack, a -5 Volt power problem is indicated. If a TN736 or TN752 power
unit circuit pack is present, the 631DB AC power unit or the 676B power
unit may be defective. The system may contain either a TN736 or a
TN752 power unit circuit pack OR a 631DB power unit, but not both
types of power units. To investigate power problems, see
(Carrier Power Supply)'' on page
''CARR-POW
8-393.
Continued on next page