Atm-Bch (Atm B-Channel Trunk) - Avaya S8700 Maintenance Manual

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures

ATM-BCH (ATM B-Channel Trunk)

MO's Name (in
Alarm Log)
Alarm Level
2
ATM-BCH
MAJOR
ATM-BCH
MINOR
ATM-BCH
WARNING
1.
UU is the universal cabinet number (1–64 for ATM PNC, 1–44 for CSS PNC). C is the carrier designation (A,
B, C, D, or E). SS is the number of the slot where the circuit pack resides (01–21). ppp is the 3-digit port number
(9–256).
2.
For additional repair information, see also
Group)''
and PKT-BUS.
3.
A MAJOR alarm on a trunk means that alarms on these trunks are not downgraded by the set options
command, and at least 75% of the trunks in this trunk group are alarmed.
This MO explains how you test and repair TN230x ATM Interface circuit packs
(TN2305 and TN2306) that have ATM B-channel trunks administered for ATM
Circuit Emulation Service (CES).
For maintenance instructions for TN230x circuit packs that are administered as
Expansion Interfaces for ATM network connectivity, see the
(TN2305/6)''
ATM Circuit Emulation Service
Under ATM Circuit Emulation Service, you simulate ISDN-PRI circuits by
assigning ATM ports to signaling groups. Each signaling group represents a PRI
circuit, and the ports in the group represent the D channel and B channels of that
circuit. B channels must also be assigned to ISDN-PRI trunk groups. TN230x
circuit packs support up to 248 ports per circuit pack.
Signaling Group Components
B (bearer) channels (ATM-BCH) transmit digitized voice or data, while a separate
D channel (ATM-DCH) handles call-control signaling. One D channel handles
signaling for a group of B channels that combine to form a signaling group
(ATM-SGRP).
B-Channel Service States
The ISDN specification defines two service state categories for B channels as
listed in
Table 8-67 on page
8-168
Issue 1 May 2002
Initial Command to
1
Run
3
test port UUCSSppp l
test port UUCSSppp l
test port UUCSSppp sh
''ATM-DCH (ATM D-Channel
MO.
8-169.
Full Name of MO
ATM B-Channel Trunk
ATM B-Channel Trunk
ATM B-Channel Trunk
Port)'',
''ATM-SGRP (ATM Signaling
''ATM-INTF
555-233-143