Avaya S8700 Maintenance Manual page 1404

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Failure Audit (#949)
This test is nondestructive.
This test queries the DS1 CONV circuit pack for any existing circuit pack or facility
failures and any unacknowledged cleared failure messages. Upon receiving the
query request, DS1 CONV firmware sends failure reports to the maintenance
software for every error in its failure database.
This test operates on both MOs DS1C-BD and DS1-FAC. Error counts of both
MOs (DS1C-BD and DS1-FAC) that are displayed in the error log will be
incremented when this test is executed. This test is executed via the test board
command. The test is also executed internally by the maintenance software when
an alarm is resolved
Table 8-267. Test #949 Failure Audit
Error
Test
Code
Result
Description / Recommendation
2100
ABORT
Could not allocate the necessary system resources to run this test.
2000
ABORT
Timed out while waiting for a response from the circuit pack.
2300
ABORT
The downlink message necessary to run this test could not be sent.
2301
ABORT
The timer could not be set before sending the downlink message necessary to
run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2316
ABORT
Fiber link is not administered. Administer the DS1 CONV fiber link via the add
fiber-link command.
2500
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
FAIL
The DS1 CONV circuit pack reported failures or retransmitted a cleared failure
message.
1. Enter display errors and follow the associated repair procedures for any
PASS
The DS1 CONV circuit pack has no failures.
8-682
Issue 1 May 2002
DS1C-BD and DS1-FAC errors.
555-233-143

Advertisement

Table of Contents
loading

Table of Contents