Avaya S8700 Maintenance Manual page 1652

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Error Log Entries and Test to Clear Values
Table 8-359. DS1 Interface Circuit Pack Maintenance Error Log Entries
Error
Aux
Type
Data
Associated Test
1
0
0
Any
1(a)
0
Circuit pack removed or
SAKI test (#53)
18(b)
0
busyout board UUCSS
23(c)
0
Board administered but not
inserted
125(d)
none
Wrong board
257(e)
65535
Control Channel Loop test
(#52)
513(f)
4352
TN2302 On board hardware
4353
errors
4355
4356
4358
769(g)
2-Way Transmission tests
(#1505 & 1506)
1025(h)
Any
FPGA Query test (#1406)
1281(i)
Any
TSI Health Query test
(#1406)
1538(j)
Any
Circuit pack is hyperactive
1793
Any
NIC Loss Of Signal
2049(k)
Any
PPC Sanity Query test
(#1406)
2305(l)
Any
IP Address Update
2561(m)
Ping error
2817(n)
Any
Ethernet Hardware Query
test (#1406)
3073(o)
Any
Circuit pack reset test (#53)
3840,
Inconsistent downlink or
3841(p)
board error
3999(q)
Any
None
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
2.
Minor alarms on this MO may be downgraded to warning alarms based on values set in the set options
command.
8-930
Issue 1 May 2002
Alarm
On/Off
Level
Board
Test to Clear Value
Any
Any
test board UUCSS
MIN/WRN
OFF
WARNING
OFF
release board UUCSS
WARNING
OFF
add ds1 UUCSS
MINOR
ON
MINOR
ON
test board UUCSS l r
20
MINOR
ON
MINOR
OFF
MINOR
MINOR
ON
MIN/
test board UUCSS l r 2
2
WRN
555-233-143

Advertisement

Table of Contents
loading

Table of Contents