DS1-BD (DS1 Interface Circuit Pack)
Table 8-245. Test #138 Loss of Signal Alarm Inquiry Test — Continued
Error
Test
Code
Result
Description / Recommendation
1324
FAIL
A non-service-affecting CSU module/T1 sync splitter audit failure was detected
by the TN767E DS1 circuit pack. No ports should be affected. No immediate
action is required. These errors indicate that the CSU module/T1 sync splitter
hardware may have a problem, and that it should be replaced when practical to
avoid further deterioration.
PASS
DS1 signal is present and the physical link is healthy. In addition, no Integrated
CSU errors are detected.
0
NO
The test could not relate the internal ID to the port (no board).
BOARD
This could be due to incorrect translations, no board is inserted, an incorrect
board is inserted, or an insane board is inserted.
1. Verify that the board's translations are correct. Use the add ds1 UUCSS
2. If board was already administered correctly, check the error log to
3. If the board was found to be correctly inserted in step 1, issue the busyout
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
555-233-143
command to administer the DS1 interface if it is not already administered.
determine whether the board is hyperactive. If so, the board was shut
down. Reseating the board will re-initialize it.
board command.
This should re-establish the link between the internal ID and the port.
Continued on next page
Issue 1 May 2002
8-609