Maintenance-Object Repair Procedures
Table 8-61. Test #618 BRI Port Local LAN Looparound — Continued
Error
Test
Code
Result
Description / Recommendation
1141
ABORT
The PKT-CTRL is out-of-service.
1. Follow the repair procedures for the PKT-CTRL.
2. Issue the test port long UUCSSpp command and review the results of the
2012
ABORT
Internal system error
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
The loop-around test has failed.
1. If the test fails repeatedly, attempt to reset the circuit pack if the other ports
2. If the test fails again, execute test pkt P on the management terminal. If
3. If the tests executed in step 2 pass, the problem is local to the BRI board.
PASS
The BRI Port Local LAN Looparound test has passed.
8-160
Issue 1 May 2002
BRI Port Local LAN Looparound test to verify the repair.
on the board are idle. Reset the circuit pack by issuing the busyout board
UUCSS and the reset board UUCSS commands.
this fails, follow the failure procedures the in PKT-BUS section.
Replace the circuit pack.