Maintenance-Object Repair Procedures
If the reset command returns "PN is unavailable," execute the following steps:
1. Use the change circuit-pack P (PN's number) command.
2. For the EI circuit pack you wish to reset, add an entry to the Circuit Pack
form for the TN570 EI circuit pack. Be sure to enter the appropriate carrier
and slot.
3. Enter the form.
4. Issue the busyout board UUCSS command.
5. Repeat the reset board command
Table 8-309. Test #336 Expansion Interface Reset Test
Error
Test
Code
Result
Description / Recommendation
4
ABORT
Could not reset the PN EI circuit pack over the optical fiber since the neighbor
EI circuit pack or SNI circuit pack is not recognized by software (inserted).
1. Insert neighbor EI circuit pack or SNI circuit pack and perform reset again.
1015
ABORT
The system will not allow this test to be run because the EI circuit pack has not
been busied out.
Busyout the EI circuit pack. Repeat the reset board UUCSS command.
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this test.
2500
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
1
FAIL
The EI did not successfully reset.
1. If the EI circuit pack is in the PN, the PN's Maintenance board may be
2. If step 1 was not successful in releasing the EI circuit pack, temporarily
3. Repeat the reset board UUCSS command.
4. If reset continues to fail, replace circuit pack.
5. Insert PN's Maintenance circuit pack if it was removed.
8-806
Issue 1 May 2002
holding the EI circuit pack reset. Attempt to rectify this condition by
executing the test maint P long command on the Maintenance board in
the same PN.
remove the PN's Maintenance circuit pack.
Continued on next page