ATM-BCH (ATM B-Channel Trunk)
Signaling Link State Audit Test (#255)
This nondestructive test checks the status of the TN230x ATM-CES Interface
circuit pack and the ATM D-channel (ATM-DCH) trunk, which are both important
elements to the health of the ATM-BCH trunk.
Table 8-71. Test #255 Signaling Link State Audit Test
Error
Test
Code
Result
Description / Recommendation
None
ABORT
Internal system error
0
ABORT
1114
ABORT
Signaling link in transitional state
1. Retry the command up to 5 times at 1-minute intervals.
1018
ABORT
Maintenance disabled
1. Enable maintenance. Enter y in the
4
FAIL
Signaling channel problem
1. Look for errors or alarms against the
8
FAIL
TN230x circuit pack failed
1. See the
PASS
Signaling link OK.
555-233-143