Maintenance-Object Repair Procedures
Service State Audit Test (#256)
This test checks the service state of the trunk.
Country protocol 1. If the interface uses country protocol 1 (includes USA), the
service-state audit executes in every trunk service state. It queries the service
state on the far end and waits 2 minutes for a reply. If the first request times out,
the service-state audit asks again. If the request times out again, it logs error
3073 and resends the request every 15 minutes. It places in-service trunks in the
MAINTENANCE/FAR-END state (outgoing calls blocked, incoming calls
accepted). Incoming calls trigger an immediate service-state audit without waiting
for the end of a 15-minute cycle.
Any other country protocol. If the interface uses some other country protocol, the
service-state audit executes only on trunks that are in the
OUT-OF-SERVICE/FAR-END state. It asks the far-end switch to bring the trunk
back into the IN-SERVICE state and waits 2 minutes for a reply. If the first request
times out, the service-state audit asks again. If the request times out again, it
leaves the trunk in the OUT-OF-SERVICE/FAR-END state and tries again in 1
hour.
NOTE:
PASS for this test only means that a message to the far end was
successfully sent.
To check the service state of the ATM-BCH trunk, run status trunk grp#/mbr#.
Table 8-72. Test #256 Service State Audit Test
Error
Test
Code
Result
Description / Recommendation
1000
ABORT
Needed resources not available, port on a call or initializing
1. Run status trunk grp#/mbr#.
1. Check the results of Test #255.
1018
ABORT
Maintenance disabled
1. Enable maintenance by entering y in the
1113
ABORT
Signaling link failed
1. Run status trunk grp#/mbr#.
2. Check the results of Test #255.
3. See the
1114
ABORT
Signaling link in transitional state
1. Retry the command up to 5 times at 1-minute intervals.
8-176
Issue 1 May 2002
on page 2 of the change trunk-group form.
''ATM-SGRP (ATM Signaling Group)''