ADX16A-PT (AUDIX Analog Line/Control Link)
Table 8-15. Test #161 Loop-Around Test — Continued
Error
Test
Code
Result
Description / Recommendation
FAIL
The reflective loop-around test failed. This causes noisy or unreliable
connections or other users calling this port may hear an echo.
1. Replace the circuit pack.
PASS
The port is able to provide an analog transmission path to the station
equipment. User-reported troubles on this port should be investigated by using
other port tests, by examining station wiring, or by examining the station.