Avaya S8700 Maintenance Manual page 1012

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Table 8-125. ATM Board Reset (#1256) — Continued
Error
Test
Code
Result
Description / Recommendation
PASS
The ATM-TRK circuit pack is successfully reset.
0
NO
No board detected.
BOARD
1. Check the error log for Error 125 (wrong board) or Error 131 (no board),
2. Ensure that the board is properly translated and inserted.
3. Check for Error 1538 (hyperactivity). If hyperactive, run reset board
4. Run the test again. If it fails, replace the ATM-TRK circuit pack, and retest.
8-290
Issue 1 May 2002
and perform the appropriate repair, if needed.
UUCSS.
Continued on next page
555-233-143