Avaya S8700 Maintenance Manual page 1166

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Table 8-180. Test #7 Conference Circuit Test — Continued
Error
Test
Code
Result
Description / Recommendation
1004
ABORT
The port has been seized by a user for a valid call.
1. Use the status station or status trunk command to determine when the
2. Retry the command at 1-minute intervals up to 5 times.
1018
ABORT
The test was disabled via translation. You may want to determine why the test
has been disabled before you enable it.
1. Verify that the
2. Repeat the test.
1020
ABORT
The test did not run due to a previously existing error on the specific port or a
more general circuit pack error.
1. Examine Error Log for existing errors against this port or the circuit pack
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2053
ABORT
At least one of the following errors was found on the DS1 circuit pack: Loss of
signal (1281), Blue alarm (1793), Red alarm (2049), Yellow alarm (2305), or
Hyperactivity (1537).
Look for the previous error types in the Hardware Error Log, and follow the
procedures given in the appropriate DS1-BD or UDS1-BD maintenance
documentation for the listed error types.
8-444
Issue 1 May 2002
port is available for testing.
Maintenance Test
screen is set to 'n.' To enable the test, change the trunk administration and
enter 'y' into the
Maintenance Test
and attempt to diagnose the previously existing error.
field on the 'Trunk Administration'
field.
Continued on next page
555-233-143

Advertisement

Table of Contents
loading

Table of Contents