Avaya S8700 Maintenance Manual page 870

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Aux Data
2
3
4
5
6
10
12
16
17
102
The switch sent a message to an endpoint that did not respond in the
allotted time. This may be due to failure of the point-to-point signaling link
or because of a problem in the ASAI adjunct. To repair:
b. An endpoint is not responding to the service state query message sent to
the adjunct or to the endpoint. This error causes an alarm to be raised.
The alarm is retired when the switch receives a response to the service
state query to the endpoint or to the adjunct.
When this error occurs for an ASAI adjunct, the Aux Data field indicates the
state of the ASAI link and whether an invalid response or no response was
received to the query from the switch, as shown in the following table:
Aux Data
102
104
152
154
202
204
See
''status bri-port'' on page 7-294
states.
8-148
Issue 1 May 2002
Timer Type
First T303 (SETUP timer)
Second T303 (SETUP timer)
T305 (DISConnect timer)
First T308 (RELease timer)
Second T308 (RELease timer)
T316 (RESTart timer)
T309 (Layer-2 Failure timer)
TM100 (Management Information message Timer 1)
TM200 (Management Information message Timer 2)
TASAI (ASAI Routing Timer)
Execute the test station extension command and perform the
associated repair procedures for those tests.
ASAI Link State
13-restarting
13-restarting
13-restarted
13-restarted
13-established
13-established
Error
No response to RESTART message
Invalid response to RESTART message
No response to layer-3 query
Invalid response to layer-3 query
No response to layer-3 query
Invalid response to layer-3 query
for an explanation of the ASAI link