DAT-LINE (Data Line Port)

DAT-LINE (Data Line Port)
MO's Name (in
Alarm Log)
DAT-LINE
DAT-LINE
1.
UU is the universal cabinet number (1–64 for ATM PNC, 1–44 for CSS PNC). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot where the circuit pack resides (01–21).
pp is the 2-digit port number (01, 02, 03 ...).
The TN726 Data Line circuit pack has eight ports, each of which supports an
RS-232 interface to asynchronous CPE (customer-premises equipment). Each of
these ports and the equipment connected to it constitute a data line. For
DT-LN-BD (Data Line circuit pack) errors, see
Pack)'' on page
the ports depend on the health of the circuit pack.
Data line ports are administered at the terminal with the add data-module
command. The data module type is data-line. The list data-module command
will list every administered data module in the system.
The TN750 Announcement circuit pack also has one data line-type port on it. This
data line port is used for saving and restoring announcements. For a description
of this feature and repair instructions for the TN750, see
(Announcement Circuit
NOTE:
If the tests for the data line port in question pass, and user-reported
complaints persist, there is probably an external problem. Test the ADU
(asynchronous data unit), following the procedures outlined in User Manual
Z3A Asynchronous Data Unit, 555-401-701. If the ADU appears to be
working properly, check the external wiring, and then check the customer
equipment.
555-233-143
Alarm
Initial SAT Command to
1
Level
Run
MINOR
test port UUCSSpp l
WARNING
test port UUCSSpp l
8-1872. Check circuit pack-level errors first since the usability of
Pack)''.
Full Name of MO
Data Line port
Data Line port
''XXX-BD (Common Port Circuit
''ANN-BD