Avaya S8700 Maintenance Manual page 1034

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Error Log Entries and Test to Clear Values
Table 8-135. Auxiliary Trunk Error Log Entries
Error
Aux
Type
Data
Associated Test
1
0
0
Any
1(a)
57481
None
1(b)
57782
15(c)
Any
Audit Update test (#36)
18
0
busyout port UUCSSpp
130(d)
None
769(b)
57482
None
257
Hybrid/Conference
Circuit test (#33)
513
NPE Crosstalk test (#6)
1025
Diagnostic test —
Auxiliary Trunk test
(#114)
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate test's
description, and follow its recommended procedures.
2.
Major or Minor alarms may be downgraded to Warning alarms based on the values used in the set options
command.
Notes:
a. Error Type 1 with Aux Data 57481 indicates a port fault. Use an empty port
if one is available until the circuit pack can be replaced.
b. Error Type 1 or 769 with Aux Data 57482 indicates a fault on signaling lead,
which is an off-board error. This error should only occur with loudspeaker
paging. If the trunk is being used for another application, check that the
administration is correct. Otherwise, check the wiring to the external
equipment connected to the Auxiliary Trunk and check the external
equipment.
c. This is a software audit error that does not indicate any hardware
malfunction. Run short test sequence, and investigate associated errors.
d. Indicates the circuit pack has been removed or has been insane for more
than 11 minutes. To clear the error, reseat or replace the circuit pack.
8-312
Issue 1 May 2002
On/
Alarm
Off
Level
Board
Test to Clear Value
Any
Any
test port UUCSSpp sh r 1
WARNING
OFF
release port UUCSSpp
WARNING
ON
test trunk grp/mbr sh
MINOR
ON
test port UUCSSpp l r 3
2
WARNING
MINOR
ON
test port UUCSSpp l r 3
2
WARNING
WARNING
ON
test port UUCSSpp sh r 3
555-233-143

Advertisement

Table of Contents
loading

Table of Contents