Avaya S8700 Maintenance Manual page 1177

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

CO-TRK (Analog CO Trunk)
Table 8-183. CO Trunk Error Log Entries — Continued
Error
Aux
Type
Data
Associated Test
1537
Dial Tone test (#0)
1793
Looparound and
Conference test (#33)
2049
NPE Cross Talk test
(#6)
2561 (d)
57345
None
2817 (a)
57360
None
2817 (a)
57393
None
2817 (d)
57484
Dial Tone test(#0)
3073 (d)
57376
None
3329 (d)
57408
None
3329 (d)
57484
Dial Tone test (#0)
3585 (d)
57424
None
3840 (f)
8000
Transmission tests
(ATMS)(#844-848)
3841 (f)
Transmission tests
(ATMS)(#844-848)
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
2.
Major alarms may be downgraded to Warning alarms based on the value used in the set options command.
Notes:
a. These are in-line errors that have no specific test associated with them.
Refer to the following table for an explanation and appropriate action.
b. This is a software audit error that does not indicate any hardware
malfunction. Run short test sequence, and investigate associated errors.
c. This error type indicates that the circuit pack has been removed or has
been insane for at least 11 minutes. To clear the error, reinsert or replace
the circuit pack.
555-233-143
Alarm
On/Off
Level
Board
MAJOR
OFF
MINOR
2
WARNING
MAJOR
ON
MINOR
2
WARNING
MAJOR
ON
MINOR
2
WARNING
MAJOR
OFF
MINOR
WARNING
MAJOR
OFF
MINOR
WARNING
OFF
MINOR
OFF
Issue 1 May 2002
Test to Clear Value
test port UUCSSpp l r 2
test port UUCSSpp l r 3
test port UUCSSpp l r 3
test port UUCSSpp l r 1
test port UUCSSpp l r 1
test analog-testcall
test analog-testcall