ATM-EI (Expansion Interface Circuit Pack)
Error Type 3585
1. If the system has duplicated PNC:
2. If the system does not have duplicated PNC and the circuit pack is
Error Type 3586 — Framer Looparound test (#1260) failed.
1. If Error Type 3586 is detected again, replace the circuit pack.
u. Error Type 3841 — The board received a message from the switch that it
does not recognize, and the board responded with an inconsistent down
link error message. This error does not affect service, and no action is
required.
v. Error type 3842 — The circuit pack received data from the packet bus
faster than it could distribute the data to its endpoint. This circuit pack
should be able to recover by itself, and no action is necessary.
w. Error type 3843 — The firmware on the circuit pack is reporting a resource
that is low. This error does not affect service and no action is required.
555-233-143
Aux Data (Error Type 3585 only):
Aux Data
Description
1
ATM framer failure
2
NCE failed (only from ATM-EIs in EPN)
4
TDM_PLD_FAILED
5
DSP_ALL FAILED
6
Receive Network Processor (RNP) failure
7
Transmit Network Processor (TNP) failure
8
MEMORY read/write failure
a. Test the ATM-EI (test board UUCSS l).
b. If Error 3585 is detected again, or if the board is not
recognized anymore, replace the ATM-EI circuit pack.
in an EPN:
a. Replace the ATM-EI circuit pack.
Aux Data (Error Code 3586 only):
Aux Data
Description
2
Packet path failed
3
Circuit path failed
4
TDM loop cannot be created
5
Packet loop cannot be created