CLAN-BD (Control LAN Circuit Pack)
PPE/LANBIC Receive Parity Error Counter
Test (#595)
This test is nondestructive. When the C-LAN circuit pack detects a parity error
with a received frame, it increments the PPE/LANBIC Receive Parity error
counter. This test reads and clears the counter, and may verify repair of problem.
Errors may indicate a problem with:
This circuit pack
A packet bus
Another circuit pack on the bus
Table 8-169. Test #595 PPE/LANBIC Receive Parity Error Counter Test
Error
Test
Code
Result
Description / Recommendation
2000
ABORT
Did not receive circuit pack test response within the allowable time period.
1. Retry command at 1-minute intervals up to 5 times.
2. If the problem persists, reset the circuit pack (reset board UUCSS).
3. If the problem persists, replace the circuit pack.
2100
ABORT
Could not allocate the necessary system resources to run test.
2500
ABORT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the problem persists, escalate the problem.
1–10
FAIL
Circuit pack detects parity errors. The Error Code indicates the value of the
on-board error counter.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to fail, execute Packet Interface test (#598) (test
3. If Packet Interface test (#598) fails, see packet-bus repair procedures.
PASS
Circuit pack detects no errors.
555-233-143
board UUCSS).
Continued on next page
Issue 1 May 2002
8-421