Maintenance-Object Repair Procedures
Notes:
a. Error Type 1—Aux Data 57408—No tip ground is detected on an outgoing
call.
The DS1 Interface circuit pack detected a hardware fault. These errors will
cause the Dial Tone test (#314) to run and are only considered a problem if
the Dial Tone test fails (in which case Error Type 1025 will also show up).
In this case, the trunk may be put in the ready-for-service state (shown as
"disconnected" by the status command), which allows only incoming calls.
Run the Dial Tone test (#314) and follow the procedures.
b. Error Type 15—This is a software audit error that does not indicate any
hardware malfunction. Run short test sequence, and investigate
associated errors (if any).
c. Error Type 18—System Technician has busied out the trunk to the
out-of-service state. No calls can be made on this trunk except Facility
Access Test Calls. For details on this feature, see
page
d. Error Type 130—This error type indicates that the circuit pack has been
removed or has been insane for more than 11 minutes. To clear the error,
reinsert or replace the circuit pack.
e. Error Type 257—The DS1 Interface circuit pack detects a hardware fault.
Aux Data 57392 indicates no external release on PBX disconnect.
f. Error Type 513—The DS1 Interface circuit pack detects a hardware fault.
Aux Data 57393 indicates belated external release on PBX disconnect.
g. Error Type 769—The DS1 Interface circuit pack detects a hardware fault.
The Aux Data field contains the following error type:—57484, fault is
detected on tip/ring.
h. The DS1Interface circuit pack detects a hardware fault, and the Aux Data
field contains the following error type: 51200, port is unavailable. Run the
Dial Tone test (#314), and follow procedures.
i. Error Type 1793—DS1 Interface circuit pack is out-of-service. Look for
UDS1-BD errors in the Hardware Error Log if the port is on a TN464 UDS1
board. See "UDS1-BD (UDS1 Interface circuit pack)" (DS1 Trunk circuit
pack) for details
j. Error Type 2049—With the following Aux Data:
8-564
Issue 1 May 2002
Aux Data 57476—Rotary Dial before Wink.
Aux Data 57477—Rotary Dial pulse too early.
Aux Data 57485—Wink too short for a valid signal.
Aux Data 57487—PBX could not get "loop close" signal.
5-15.
Aux Data 57473—Rotary dial rate below 8 pulses per second.
Aux Data 57474—Rotary dial rate above 12 pulses per second.
Aux Data 57475—Rotary Dial interdigit time is too short.
''Facility Test Calls'' on
555-233-143