Maintenance-Object Repair Procedures
Table 8-231. Test #314 DS1 CO Dial Tone Seizure Test — Continued
Error
Test
Code
Result
Description / Recommendation
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2053
ABORT
At least one of the following errors is found on the DS1 circuit pack:
Look for the above error types in the Hardware Error Log and follow the
procedures given in the appropriate DS1-BD or UDS1-BD maintenance
documentation for the listed error types.
FAIL
The trunk cannot be seized for an outgoing call.
1. Verify that the
2. Look for UDS1-BD errors in Hardware Error Log. If present, see
3. Retry the test at 1-minute intervals up to 5 times.
PASS
The trunk can be seized for an outgoing call.
8-572
Issue 1 May 2002
1281—Loss of signal
1793—Blue Alarm
2049—Red Alarm
2305—Yellow Alarm
1537—Hyperactivity
Trunk Type
matches the trunk type administered on far-end switch.
''UDS1-BD (UDS1 Interface Circuit Pack)'' on page
field on the trunk administration screen form
8-1707.