Maintenance-Object Repair Procedures
Table 8-337. Test #42 Tone Detection Verification Test — Continued
Error
Test
Code
Result
Description / Recommendation
1003
ABORT
The system could not allocate a Tone-Clock for the test connection. This may
be caused by a heavy load on the system or by a faulted Tone-Clock.
1. Check to see if there are any alarms against the Tone-Clock in the port
2. If a new Tone-Clock has been inserted, allow about 1 minute for
3. Retry the command at 1-minute intervals up to 5 times.
2000
ABORT
Response to the test request was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2006
ABORT
The active Tone-Clock circuit pack or a Tone Detector circuit pack may not be
functioning properly.
1. Test the active Tone-Clock circuit pack in the port network with the test
2. Retry the command at 1-minute intervals up to 5 times.
2100
ABORT
Could not allocate the necessary system resources to run this test.
Retry the command at 1-minute intervals up to 5 times.
101–
FAIL
1. Run the short test sequence: test port UUCSSpp sh r 1.
122
2. If the problem persists, the system is still operating properly but system
1022
FAIL
Tone detection for the system is administered as part of a wideband
configuration, and the tone detector is not a TN420C (the only circuit pack with
this capability). GPTD ports on other types of tone detector circuit packs are
taken out of service since they cannot provide the administered function.
1. Change the tone-detection mode administered on the system-parameters
PASS
Tone Detection Verification is successful. The GPTD port is able to detect
every call-progress tone and perform level measurements of test tones.
8-886
Issue 1 May 2002
network where the test aborted. If so see the recommended procedures
for
''TONE-BD (Tone-Clock Circuit)''
maintenance to run on the newly inserted circuit pack.
tone-clock UUC command and see
failures.
capacity will be reduced. In order to restore the system performance to
normal, replace the tone detector circuit pack containing the defective
GPTD port.
country-options form, or remove every circuit pack except TN420C tone
detectors from the system.
or
''TONE-PT (Tone
Generator)''.
''TONE-BD (Tone-Clock Circuit)''
Continued on next page
555-233-143