Avaya S8700 Maintenance Manual page 1513

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

EXP-INTF (Expansion Interface Circuit Pack)
Table 8-305. Test #240 Expansion Interface Local Looparound — Continued
Error
Test
Code
Result
Description / Recommendation
1032
ABORT
The EI cannot detect the framing signal and cannot run the test.
1. Refer to the errors for Test #238 to determine why the EI circuit pack is out
1033
ABORT
The EI circuit pack does not have a fiber link administered to it. There is not
sufficient data to run test.
1. Issue the list fiber-link command to verify that there is no fiber link
2. If there is no fiber administered to this circuit pack, but there should be add
3. Retry the command.
1394
ABORT
The EI circuit pack is out of service and the test cannot be run. This condition
is due to a change in the EI circuit pack's ability to communicate with the EI or
SNI circuit pack on the other end of the fiber.
1. Run Test #237, and check the Error Log for EXP-INTF error type 1281. If
1395
ABORT
This test cannot be run on an EI circuit pack if it is part of the B-side PNC and
duplicated PNC is not enabled.
1. If this test needs to run on this EI circuit pack, enable PNC with the change
2. Prevent the system from doing a PNC interchange by executing the set
3. Repeat this test.
2000
ABORT
Response to the test was not received within the allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this test.
2500
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
555-233-143
of frame.
administered to this circuit pack.
the correct fiber using the add fiber-link command.
error type 1281 is present or if Test #237 does not pass, see repair
procedures for Test #237, in
system-parameters duplication command.
PNC lock command.
Table 8-303 on page
8-787.
Continued on next page
Issue 1 May 2002
8-791

Advertisement

Table of Contents
loading

Table of Contents