Avaya S8700 Maintenance Manual page 1013

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

ATM-TRK (Circuit Emulation Service Circuit Pack)
ATM Board Error Query Test (#1259)
This nondestructive ATM Error Query test retrieves the most severe, active, on-
and off-board problem from the ATM-TRK circuit pack's firmware and increments
error counts in the Error Log.
The test passes if there are no errors and fails otherwise. A passing test clears
the software counters; a failure increments the counter associated with the
problem that caused the failure and clears the others.
Table 8-126. ATM Board Error Query Test (#1259)
Error
Test
Code
Result
Description / Recommendation
2000
ABORT
Test request timed out.
2031
ABORT
SCD failure. Unable to sent down-link message.
2100
ABORT
Could not allocate needed system resources.
2500
ABORT
Internal system error
1. Retry the command up to 3 times at 1-minute intervals.
XXYY
FAIL
On-board error XX
page
1. Examine the error logs and repair any errors found.
PASS
The ATM circuit pack has passed this test. No service effecting errors/alarms
have been detected on board.
0
NO
ATM-TRK circuit pack not found
BOARD
1. Check the error log, and correct Error 125 (wrong board) or Error 131 (no
2. Make sure that the board is properly translated and inserted.
3. Check for hyperactivity (Error 1538). Run reset board UUCSS if
4. Run the test again. If it fails, replace the board, and retest.
555-233-143
(Table
8-127) and/or off-board error YY
8-292).
board), if found.
hyperactive.
(Table 8-128 on
Continued on next page
Issue 1 May 2002
8-291

Advertisement

Table of Contents
loading

Table of Contents