Maintenance-Object Repair Procedures
f. Error Type 1793: Layer 2 Query test for the primary signaling channel
failed.
g. Error Type 2305: The Remote Layer 3 Query test (#637) failed. A specific
message was sent to the far-end switch, and it did not respond within the
allotted time.
1. Investigate elements of the ATM D channel(s) (ATM-DCH) for both
If Test #637 fails twice in a row, the B channels are alarmed and made
unavailable for outgoing calls (although incoming calls are still accepted).
When Test #637 succeeds and the far-end switch starts responding
properly, the ATM trunk (B channels) are placed back into normal operation
and their alarms retired.
h. Error Type 3585: A SERV or SERV ACK ISDN D-channel message has
been received by a non-US-type interface (country option other than 1 on
the DS1 administration form). However, these messages are used only for
duplex NFAS signaling, which is supported by country protocol 1.
Thus, there may be a mismatch in administration between the local and
far-end switches.
1. Consult with the customer's network provider to determine whether
i. Error Type 3840-3928: These error types are used to report certain error
messages received by the ATM-SGRP Signaling Group for one of its
associated B channels. The Aux Data field is the port number of the
B channel from which the message was received.
The error code generated equals 3840+x, where x is a Cause Value
defined by the ISDN PRI Specification. Note that there is no Test to Clear
Value for these error types; selected ISDN cause values are placed in the
log when they are received, but no direct action or alarming is performed
solely in response to receiving them. They provide added data that may
prove useful when tracking down obscure networking and routing
problems.
this range of Error Codes:
8-256
Issue 1 May 2002
Excessive AAL – The AAL layer is experiencing an excessive
number of errors in trying to reconstruct Service Data Unit (SDUs).
Possible causes:
— Problem with the ATM switch
— Noisy communication paths on opposite side of ATM switch
— Unhealthy sending node
— Congestion at the ATM switch
this switch and the far-end switch.