Maintenance-Object Repair Procedures
1. Execute the list fibers command to determine the Fiber Endpoint
2. If the problem still persists, check for excessive slips and
3. If the problem still persists, run the Far-End DS1 CONV Circuit Pack
4. If the problem still persists, run the Far-End Fiber Optic Terminator
5. If the problem still persists, replace connectors and the cable
t. Fiber Loss of Signal (LOS) alarm occurred at the other end of the DS1
CONV complex. The DS1 CONV circuit pack at the other end of the DS1
CONV complex does not detect a signal coming into the circuit pack from
the fiber. (The neighbor DS1 CONV circuit pack detected the LOS and
relayed this information to this DS1 CONV circuit pack via the DS1
Channel.) The amber LED will flicker at a 5-Hz rate (on for 0.1 second, off
for 0.1 second).
1. Execute the list fibers command to determine the Fiber Endpoints
2. If the problem still persists, run the Far-End DS1 CONV circuit pack
8-704
Issue 1 May 2002
that is connected to the DS1 CONV circuit pack. Enter display
errors and follow the associated repair procedures for any
EXP-INTF, and SNI-BD errors for the Fiber Endpoints. Enter
display errors and follow the associated repair procedures for any
FIBER-LK errors for this fiber link.
synchronization problems. Enter display errors and follow the
associated repair procedures for any SYNC, TDM-CLK, and
SNC-BD errors.
Loopback test (#788) on this DS1 CONV circuit pack via the test
board UUCSS long command. This test will indicate if the neighbor
DS1 CONV circuit pack hardware is functioning. If this test fails,
replace the DS1 CONV circuit pack at the other end of the DS1
CONV complex.
(lightwave transceiver) Loopback test (#789) on this DS1 CONV
circuit pack via the test board UUCSS long command. If this test
fails, replace the lightwave transceiver that is connected to the
neighbor DS1 CONV circuit pack at the other end of the DS1 CONV
complex. (If the neighbor board is connected to the Fiber Endpoint
via metallic cable, then this test will abort.)
between the neighbor DS1 CONV circuit pack and the Fiber
Endpoint at the other end of the DS1 CONV complex. The cable
may be a fiber or a metallic cable.
that are connected to both ends of this DS1 CONV complex. Enter
display errors and follow the associated repair procedures for any
EXP-INTF, and SNI-BD errors for the Fiber Endpoints that are
administered on this fiber link, and Enter display errors and follow
the associated repair procedures for any FIBER-LK errors for this
fiber link.
loop-back test (#788) on this DS1 CONV circuit pack via the test
board UUCSS long command. This test will show if the neighbor