DID-TRK (Direct Inward Dial Trunk)
Table 8-211. Test #35 Port Diagnostic Test — Continued
Error
Test
Code
Result
Description / Recommendation
61446
FAIL
Battery feed test failed. A loop current fault was detected. This is most
probably an incoming CO-line problem. This failure code is only reported by
the TN2139 Italian DID circuit pack.
1. Check the incoming CO-line for loop current. If none is detected refer the
2. If the CO-line checks out OK, the failure must be on the DID port. Replace
61456
FAIL
Battery feed test failed. An on-board problem was detected. This port is
out-of-service.
1. Replace the circuit pack.
61472
FAIL
Battery feed test failed. A problem with the incoming CO-line was detected.
1. Check the incoming CO-line for proper operation. If warranted, refer the
2. If the CO-line is not at fault, the failure must be on the DID port. Replace
PASS
Current flow was detected for this port.
1. User-reported troubles on this port should be investigated using other port
2. Refer problem to the CO.
0
NO
The test could not relate the internal ID to the port (no board).
BOARD
1. Verify that the board's translations are correct. Translate the board if
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board command.
555-233-143
problem to the CO.
the circuit pack.
problem to the CO.
the circuit pack.
tests and by examining connections.
necessary.
This should re-establish the linkage between the internal ID and the port.