Avaya S8700 Maintenance Manual page 1045

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

BRI-BD/LGATE-BD (ISDN-BRI Line Circuit Pack)
Table 8-140. BRI-BD Error Log Entries — Continued
Error
Type
Aux Data
2306 (j)
3330 (k)
46083
3840 (l)
4096
to
4101
3843 (m)
46097
3999 (n)
Any
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
Notes:
a. This error indicates the circuit pack totally stopped functioning or it was
physically removed from the system.
If the circuit pack is not in the system, insert a circuit pack (in the same slot
as the error indicates) to resolve this error. Or, if the circuit pack is in the
system and the red LED is on, then follow the instructions for "Red (alarm)"
in
Chapter 6, ''LED
b. This circuit pack has been busied out via the busyout board UUCSS
command.
c. Port(s) has (have) been administered on this circuit pack but the circuit
pack is not physically present.
d. This error indicates transient communication problems between the switch
and this circuit pack. Execute the test board UUCSS command and see
''Control Channel Loop-Around Test (#52)'' on page 8-1734
procedures.
e. An on-board hardware failure has been detected by the circuit pack.
555-233-143
Alarm
Associated Test
Level
LANBIC Receive
Parity Error
Counter test
(#595)
MINOR
None
NOTE:
The alarm is logged approximately 11 minutes after the circuit pack
has been removed and/or SAKI Sanity test (#53) fails.
Interpretation''.
On/Off
Board
Test to Clear Value
OFF
Continued on next page
for the repair
Issue 1 May 2002
8-323