EXP-INTF (Expansion Interface Circuit Pack)
Table 8-307. Test #242 Expansion Interface Lightwave Transceiver Looparound
— Continued
Error
Test
Code
Result
Description / Recommendation
1139
ABORT
The packet bus in the PN where this EI board resides has a major alarm
against it. This test needs to use the alarmed PN's packet bus.
1. Enter display alarms and display errors and resolve any PKT-BUS
2. Retry the command.
1141
ABORT
The Packet Interface circuit pack is out of service.
1. See
1144
ABORT
The PN's packet bus has a major alarm against it. This test needs to use the
alarmed PN's packet bus.
1. Enter display alarms and display errors and resolve any PKT-BUS
2. Retry the command.
1394
ABORT
The EI board is out of service and the test cannot be run. This condition is due
to a change in the EI board's ability to communicate with the EI or SNI circuit
pack on the other end of the fiber.
1. Run Test #237 and check the Error Log for EXP-INTF Error Type 1281. If
1395
ABORT
This test cannot be run on an EI circuit pack if it is part of the B-side PNC and
duplicated PNC is not enabled.
1. If this test needs to run on this EI circuit pack, enable PNC with the change
2. Prevent the system from doing a PNC interchange by executing the set
3. Repeat this test.
1407
ABORT
This test cannot be run on an EI board that is on the active PNC because it
cannot be busied out. This error code indicates that PNC duplication is
enabled.
1. Attempt to perform a PNC interchange via the reset pnc interchange
2. If the PNC interchange is successful, busyout the original EI circuit pack
3. Retry the command.
2000
ABORT
Response to the test was not received in the allowable time period.
1. Retry the command at 1-minute intervals up to 3 times.
555-233-143
alarms.
''PKT-INT (Packet
Interface)''.
alarms.
Error Type 1281 is present or if Test #237 fails, see repair procedures for
Test #237, in
Table 8-303 on page
system-parameters duplication command.
PNC lock command.
command.
via the busyout board UUCSS (address of the original EI board).
8-787.
Continued on next page