Maintenance-Object Repair Procedures
Table 8-331. Test #989 SNI Fiber Out of Frame Query — Continued
Error
Test
Code
Result
Description / Recommendation
146
FAIL
The SNI circuit pack (Endpoint 1 of the fiber link) has a fiber out-of-frame
condition, and a loss-of-signal condition. Also, no lightwave transceiver is
connected to the SNI circuit pack.
1. Check that the connected circuit pack is physically installed. The
2. Perform the
3. Replace this SNI circuit pack.
4. Replace the connected circuit pack.
241
FAIL
The SNI circuit pack (Endpoint 2 of the fiber link) has a fiber out-of-frame
condition, but no loss-of-signal condition. Also, a lightwave transceiver is
connected to the SNI circuit pack.
1. Check that the connected circuit pack is physically installed. The
2. Perform the
3. Replace this SNI circuit pack.
4. Replace the connected circuit pack.
242
FAIL
The SNI circuit pack (Endpoint 2 of the fiber link) has a fiber out-of-frame
condition, but no loss-of-signal condition. Also, no lightwave transceiver is
connected to the SNI circuit pack.
1. Check that the connected circuit pack is physically installed. The
2. Perform the
3. Replace this SNI circuit pack.
4. Replace the connected circuit pack.
8-866
Issue 1 May 2002
connected circuit pack is the other endpoint of the fiber link if no DS1
CONV complex is administered (check via list fiber-link). Otherwise, if a
DS1 CONV complex is administered, the connected circuit pack is the DS1
CONV circuit pack connected to the SNI circuit pack.
''Fault Isolation for Fiber Links'' on page 4-19
connected circuit pack is the other endpoint of the fiber link if no DS1
CONV complex is administered (check via list fiber-link). Otherwise, if a
DS1 CONV complex is administered, the connected circuit pack is the DS1
CONV circuit pack connected to the SNI circuit pack.
''Fault Isolation for Fiber Links'' on page 4-19
connected circuit pack is the other endpoint of the fiber link if no DS1
CONV complex is administered (check via list fiber-link). Otherwise, if a
DS1 CONV complex is administered, the connected circuit pack is the DS1
CONV circuit pack connected to the SNI circuit pack.
''Fault Isolation for Fiber Links'' on page 4-19
in Chapter 5.
in Chapter 5.
in Chapter 5.
Continued on next page
555-233-143