CO-DS1 (DS1 CO Trunk)
Table 8-179. Test #6 NPE Crosstalk Test — Continued
Error
Test
Code
Result
Description / Recommendation
1004
ABORT
The port was seized by a user for a valid call.
1. Use the display port UUCSSpp command to determine the trunk
2. If the port status is idle, retry the command at 1-minute intervals up to 5
1020
ABORT
The test did not run due to a previously existing error on the specific port or a
more general circuit pack error.
1. Examine Error Log for existing errors against this port or the circuit pack
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2053
ABORT
At least one of the following errors was found on the DS1 circuit pack: Loss of
signal (1281), Blue alarm (1793), Red alarm (2049), Yellow alarm (2305), or
Hyperactivity (1537).
1. Look for the previous error types in the Hardware Error Log, and follow the
FAIL
The NPE of the tested port was found to be transmitting in error. This will
cause noisy and unreliable connections.
1. Replace the circuit pack.
PASS
The port is correctly using its allocated time slots. User-reported troubles on
this port should be investigated using other port tests and examining station,
trunk, or external wiring.
555-233-143
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the port is active, wait until it is
idle before testing.
times.
and attempt to diagnose the already existing error.
procedures given in the appropriate DS1-BD or UDS1-BD maintenance
documentation for the listed error types.
Continued on next page
Issue 1 May 2002
8-441