Maintenance-Object Repair Procedures
Table 8-32. Test #161 Loop-Around Test — Continued
Error
Test
Code
Result
Description / Recommendation
1018
ABORT
The test has been disabled by administration. The default for the
on the station form is y. Determine why this field has been set to n on this
station (this may be due to the ringing application test 48, that can be customer
or terminal disturbing).
1. To enable the test for a particular station being tested, enter change
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this test. This could
be due to a failure to seize the port.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
The reflective loop around test failed. This could cause noisy or unreliable
connections, or users calling this port may hear an echo. The problem can also
be off-board.
1. Since the test may be affected by a line seizure, repeat the test at 1-minute
2. Run circuit pack tests to check the IPSI Tone Generator circuit or the Tone
3. Resolve any problems on the Tone Generator circuit or the Tone Detector
4. If the Tone Generator and Tone Detector circuits are functioning properly
PASS
The port is able to provide an analog transmission path to the station
equipment. User-reported troubles on this port should be investigated by using
other port tests, by examining station wiring, or by examining the station. Refer
to
''LA85 Port Tester''
8-78
Issue 1 May 2002
station extension and set the
intervals up to 5 times.
Generator circuit pack and the IPSI Tone Detector circuit or the Tone
Detector circuit pack by using the test board UUCSS short command.
circuit.
and the test still fails and a voice terminal is connected and wired properly,
replace the analog line circuit pack.
in
Chapter 4
Test?
field on the station from n to y.
for instructions on using the port tester.
Continued on next page
Test
field
555-233-143