Avaya S8700 Maintenance Manual page 1035

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

AUX-TRK (Auxiliary Trunk)
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the table below when inspecting
errors in the system. For example, by clearing error codes associated with the
Looparound and Conference test (#33), you may also clear errors generated from
other tests in the testing sequence.
Order of Investigation
Looparound and Conference test (#33)
NPE Crosstalk test (#6)
Diagnostic test (#114)
Audit Update test (#36)
1.
D = Destructive; ND = Nondestructive
NPE Crosstalk Test (#6)
The NPE Crosstalk test verifies that this port's NPE channel talks on the selected
time slot and never crosses over to time slots reserved for other connections. If
the NPE is not working correctly, 1-way and noisy connections may be observed.
This test is part of a port's long test sequence and executes in about 20 to 30
seconds.
Table 8-136. Test #6 NPE Crosstalk Test
Error
Test
Code
Result
Description / Recommendation
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times
1000
ABORT
System resources required to run test are not available. The port may be busy
with a valid call.
1. Use the display port UUCSSpp command to determine the trunk
2. Retry the command at 1-minute intervals up to 5 times.
1001
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
555-233-143
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the port is active, wait until it is
idle.
Short Test
Long Test
Sequence
Sequence
X
X
X
X
X
X
Continued on next page
Issue 1 May 2002
1
D/ND
ND
ND
ND
ND
8-313

Advertisement

Table of Contents
loading