Maintenance-Object Repair Procedures
Ethernet Local Loop-around Test (#1278)
This test is destructive.
Use this test to check circuitry in the data path for an Ethernet call (from the
on-board processor to the Ethernet Transceiver). This test fails if the data it
receives does not match the data it transmits.
Table 8-292. Test #1278 Ethernet Local Loop-Around Test
Error
Test
Code
Result
Description / Recommendation
1000
ABORT
The port is in use.
1. Determine status of port (status clan-port UUCSSpp).
2. Retry the command when the port is idle. The post may be forced to the
2000
ABORT
Did not receive circuit pack test response within the allowable time period.
1. If the problem persists, reset the circuit pack (busyout board UUCSS,
2. If the problem persists, replace the circuit pack.
2012
ABORT
Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. If the problem persists, escalate the problem.
2100
ABORT
Could not allocate the necessary resources to run test.
1. Retry the command at 1-minute intervals, up to 5 times.
2. If the problem persists, escalate the problem.
1
FAIL
Circuit pack detected failure in the Ethernet Local Looparound test (#1278).
1. If the problem persists, reset the circuit pack (busyout board UUCSS,
2. If the problem persists, replace the circuit pack.
PASS
The circuitry tests properly.
8-748
Issue 1 May 2002
idle state by executing a busyout port UUCSS command.
NOTE:
The busyout port command is destructive, causing every call and link
associated with the port to be torn down.
reset board UUCSS, and release board UUCSS).
reset board UUCSS, and reset board UUCSS).
555-233-143