Maintenance-Object Repair Procedures
Table 8-328. Test #759 Configuration Audit — Continued
Error
Test
Code
Result
Description / Recommendation
233
FAIL
No neighbor link is assigned, but the SNI (Endpoint 2) has an EI neighbor.
(The list fiber-link command can be used to display a fiber link's endpoints.)
If the SNI should have an EI neighbor:
1. Issue add fiber-link next to assign the fiber link's SNI to its physically
If not:
1. Remove both fiber endpoints (i.e., this SNI and its EI neighbor).
2. Issue change circuit-pack to remove the fiber endpoints from circuit-pack
234
FAIL
No neighbor link is administered, but the SNI (Endpoint 2) has an SNI neighbor
(The list fiber-link command can be used to display a fiber link's endpoints).
1. Administer the SNI on a fiber link to the SNI neighbor it is connected to via
235
FAIL
The SNI circuit pack (Endpoint 2) cannot communicate with its neighbor. (The
list fiber-link command can be used to display fiber link endpoints.) The SNI
has an administered neighbor, but cannot communicate with its neighbor.
1. Check if the administered neighbor is inserted. If not, insert the neighbor
2. Perform the
236
FAIL
The Endpoint 2 SNI's administered neighbor does not match the physical
neighbor connected. (The list fiber-link command displays a fiber link's
endpoints.) The SNI's assigned neighbor is another SNI, but the SNI is
physically connected to an EI. Enter list fiber-link, and verify that the
fiber-optic and metallic cables are installed as administered.
237
FAIL
The Endpoint 2 SNI's administered neighbor does not match the physical
neighbor connected. (The list fiber-link command displays a fiber link's
endpoints.) The SNI's assigned neighbor is an EI, but the SNI is physically
connected to another SNI. Enter list fiber-link, and verify that the fiber-optic
and metallic cables are installed as administered.
8-858
Issue 1 May 2002
connected EI neighbor.
administration.
the add fiber-link next command. Or remove both fiber endpoints (i.e.,
this SNI and its SNI neighbor) and remove the fiber endpoints from circuit
pack administration via change circuit-pack.
circuit pack.
''Fault Isolation for Fiber Links'' on page
4-19.