Avaya S8700 Maintenance Manual page 1456

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Station Lamp Updates Test (#16)
This test lights every lamp on the terminal as specified. The lamp updates will run
only if the station is in service. The status of the station is checked and the lamp
updates are blocked from taking place if the station is not in the in-service state.
This test does not affect the status of the Message Waiting lamp.
Table 8-285. Test #16 DIG-LINE Station Lamp Updates Test
Error
Test
Code
Result
Description / Recommendation
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1
ABORT
System technician may have busied out the port.
1. Look for Error Type 18 (port busied out) for this port. If this error type is
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
3
ABORT
Station may be in ready-for-service or out-of-service state.
1. Use the status station command to verify state of station.
2. Make sure the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
1000
ABORT
System resources required to run this test are not available. The port is busy
with a valid call.
1. Use display port UUCSSpp to determine the station extension or
2. Use status station or status attendant to determine the service state of
3. Retry the command at 1-minute intervals up to 5 times.
8-734
Issue 1 May 2002
present, then release the port (release station extension) and run the test
again.
attendant number of the port.
the port. If the port is in use, wait until it is idle before retesting. Attendants
are always in use (off-hook) if the handset is plugged in and the port is not
busied out.
Continued on next page
555-233-143

Advertisement

Table of Contents
loading

Table of Contents