Maintenance-Object Repair Procedures
Diagnostic Test
Auxiliary Trunk Test (#114)
The system software sends a message to the on-board microprocessor to operate
a relay in the port circuit. If ground is detected, the test passes.
Table 8-139. Test #114 Diagnostic Test—Auxiliary Trunk Test
Error
Test
Code
Result
Description / Recommendation
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABORT
System resources required to run this test are not available. The port may be
busy with a valid call.
1. Use the display port UUCSSpp command to determine the trunk
2. Retry the command at 1-minute intervals up to 5 times.
1004
ABORT
The port was seized by a valid call during the test. The test has been aborted.
1. Use the display port UUCSSpp command to determine the trunk
2. Retry the command at 1-minute intervals up to 5 times.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
This test failed to detect ground.
1. Try the test once more.
2. If the test fails again, replace the circuit pack.
PASS
This test passed. Ground was detected.
8-318
Issue 1 May 2002
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the port is active, wait until it is
idle.
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the port is active, wait until it is
idle.