ATM PNC-DUP (ATM PNC Duplication)
Error Log Entries
Whenever a PNC interchange takes place, an error is logged against PNC-DUP
with a code that conveys information about the cause of the interchange and
which PNC became active. There are no alarms associated with PNC-DUP
errors, but there should be an alarm against the PNC component that caused the
interchange. There are no PNC-DUP test sequences, but status pnc provides
information regarding the status of the PNCs. The information in
page 8-109
Alarm Log to investigate to find the source of the problem.
Table 8-102. Error Code descriptions and Aux Data correlations
Error
Code
Description
00000
Error in generating error code
1cxpp
Spontaneous Interchange in response to a constraint for A-PNC
2cxpp
Spontaneous Interchange in response to a constraint for B-PNC
51000
Spontaneous Interchange at expiration of SOH validation timer
52000
Spontaneous Interchange upon PNC UNLOCK
53000
Spontaneous Interchange at completion of Global Refresh
60801
PNC Demand Interchange
60800
PNC Demand Interchange with override
1.
The Aux Data indicates which PNC became active after the PNC interchange: "0" denotes PNC-A; "1" denotes
PNC-B.
555-233-143
and
Table 8-103 on page 8-252
Table 8-42 on
can help to identify which areas of the
Issue 1 May 2002
1
Aux Data
None
Active PNC
Active PNC
Active PNC
Active PNC
Active PNC
Active PNC
Active PNC
8-251