Avaya S8700 Maintenance Manual page 1449

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

E-DIG-STA (Emulated Digital Line)
Hardware Error Log Entries and
Test to Clear Values
Table 8-282. Digital Line Error Log Entries - E-DIG-STA
Error
Aux
Type
Data
Associated Test
1
0
0
Any
18 (a)
0
busyout port
UUCSSpp
130 (b)
None
257 (c)
40971
None
1537 (d)
40968
None
1793 (e)
Voice and Control Local
Loop test (#13)
2049 (f)
NPE Crosstalk test (#9)
2305 (g)
32770
None
3840 (h)
40965
None
3841 (i)
41029
None
2304 (j)
None
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate test's
description, and follow its recommended procedures.
2.
Major alarms may be downgraded to Warning alarms based on the value used in the set options command.
Notes:
a. Maintenance personnel have busied out the port in question. Make sure
that the port is released from busyout by using the release port UUCSSpp
command.
b. The circuit pack has been removed or has been insane for more than
21 minutes. To clear the error, reinsert or replace the circuit pack.
c. Problems transmitting to the voice terminal. This problem can be caused
by defective wiring that can cause varying degrees of problems on different
types of sets. Sets such as the 7410 appear to be more susceptible to
wiring problems than others.
555-233-143
Alarm
On/Off
Level
Board
Any
Any
WARNING
OFF
WARNING
ON
WARNING
OFF
MINOR
ON
2
WARNING
MINOR
ON
2
WARNING
Issue 1 May 2002
Test to Clear Value
test port UUCSSpp sh r 1
rel port UUCSSpp
test port UUCSSpp sh
test port UUCSSpp l r 3
test port UUCSSpp l r 3
Continued on next page
8-727

Advertisement

Table of Contents
loading