Avaya S8700 Maintenance Manual page 1134

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Error Log Entries and Test to Clear Values
Table 8-166. CLAN-BD Error Log Entries
Error
Aux
Type
Data
Associated Test
1(a)
0
18 (b)
0
217 (c)
0
None
257
65535
Control Channel
Loop test (#52)
257 (d)
513 (e)
4352-
4357
769 (f)
4358
1293 to
Any
1295 (g)
1537(h)
Any
1794 (i)
1798 (j)
2049 (k)
Packet Interface test
(#598)
2305
2306 (l)
2561 to
Any
2668 (m)
2817
Congestion Query
2819 (n)
test (#600)
3073 (o)
Link Status test
(#601)
3330 (p)
3586 (q)
3999 (q)
Any
None
3840 (r)
4096-
4102
3841
3843 (s)
8-412
Issue 1 May 2002
Alarm
On/Off
Level
Board
MINOR
ON
WARNING
OFF
WARNING
ON
MINOR
ON
MINOR
ON
MINOR
ON
MINOR
ON
MINOR
ON
MINOR
ON
MINOR
ON
MINOR
ON
MINOR
ON
Test to Clear Value
release board UUCSS
test board UUCSS l r 20
reset board UUCSS
test board UUCSS l r 3
test board UUCSS s r 3
test board UUCSS s
reset board UUCSS
Continued on next page
555-233-143

Advertisement

Table of Contents
loading

Table of Contents