Avaya S8700 Maintenance Manual page 1214

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Table 8-198. Test #6 NPE Crosstalk Test — Continued
Error
Test
Code
Result
Description / Recommendation
1002
ABORT
The system could not allocate time slots for the test. The system may be under
heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors.
1. Resolve any TDM-BUS errors.
2. If the system is not handling heavy traffic, retry the command at 1-minute
1003
ABORT
The system could not allocate a tone receiver for the test. The system may be
oversized for the number of tone detectors present, or some tone detectors
may be out-of-service.
1. Resolve any TTR-LEV and TONE-PT errors.
2. If neither condition exists, retry the command at 1-minute intervals up to 5
1004
ABORT
The port was in use on a valid call.
1. Determine whether the port is available for testing (status data-module).
2. When available, retry the command at 1-minute intervals up to 5 times.
1020
ABORT
An existing Error Type 769 on this port prevented the test from running.
1. Follow the procedures for Error Type 769.
2000
ABORT
Response to the test command was not received within the allowable time
period.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
Any
FAIL
The NPE of the tested port was transmitting in error, which can cause noisy
and unreliable connections.
1. Replace the circuit pack.
PASS
The port is correctly using its allocated time slots.
1. Investigate user-reported troubles on this port using other port tests and
8-492
Issue 1 May 2002
intervals up to 5 times.
times.
examining the ADU, external wiring, and customer equipment.
Continued on next page