Avaya S8700 Maintenance Manual page 1504

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Table 8-301. EXP-INTF Error Log Entries — Continued
Error
Aux
1
Type
Data
Associated Test
3075 (n)
1
EI Packet Interface test
(#589)
3076
EI Packet Interface test
(#589)
3330(o)
Any
None
3585(p)
0
None
3841(q)
Any
None
3842(r)
Any
None
10001(t)
0
None
1.
Aux Data 32767 for any error log entry indicates that an alarmed EI was busied out and then released. When this
occurs, existing service affecting alarms must be preserved. As is typical, when the EI is released every alarm is
resolved. Therefore the alarm and error logs must be repopulated with the alarms present at time of busyout. This
error code is an indication that existing aux data and error log time stamps are no longer valid because they were
lost when the alarms were resolved upon release of the circuit pack.
2.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate test's
description, and follow its recommended procedures.
Notes:
a. This error indicates that the EI circuit pack has been busied out via the
busyout board UCSS command. To resolve this error, release the EI
circuit pack via the release board UCSS command.
b. EI circuit pack has been administered on the Circuit Pack form, but has not
been physically inserted into the system. Insert the circuit pack.
c. A different circuit pack occupies the slot where this circuit pack is logically
administered. To resolve this problem, either:
d. This alarm is raised after an EI circuit pack has been removed from a slot
for 5 minutes. The alarm will be resolved when the EI circuit pack is
physically inserted into this slot and becomes recognized by software.
8-782
Issue 1 May 2002
Replace the incorrect circuit pack with the logically assigned circuit
pack.
Use the change circuit-pack command to reassign the slot to
match the existing circuit pack. (If a fiber is assigned for the existing
circuit pack, remove the fiber from translations before changing the
circuit pack's translations.)
Alarm
On/Off
Level
Board
Test to Clear Value
MAJOR
OFF
test board UUCSS r 3
MAJOR
OFF
test board UUCSS r 3
WARNING
ON
WARNING
OFF
MINOR
OFF
(s)
MINOR
OFF
(s)
Continued on next page
555-233-143

Advertisement

Table of Contents
loading

Table of Contents