Avaya S8700 Maintenance Manual page 1450

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
d. An in-link maintenance error has generated an off-board warning due to
some problem with the link to the voice terminal. This can be ignored if no
user complaints are received. Otherwise, make sure the voice terminal is
connected, check for defective wiring, check for a defective voice terminal,
and move voice terminal to a jack that is closer to the switch (number of
feet of wiring between the jack and the switch). If the problem still exists,
replace the circuit pack. Once the problem has been resolved, the alarm is
retired after a predetermined amount of time.
e. The local loop test failed. Each failure increments the counter by 1 when
the local loop test fails. The counter is decremented when the loop test
passes. When the counter reaches a threshold of 3, an on-board MINOR
alarm is raised.
f. The NPE Crosstalk test failed. The counter is incremented by 1 when the
NPE Crosstalk test fails. The counter is decremented by 1 when the NPE
Crosstalk test passes. When the counter reaches a threshold of 3, an
on-board MINOR alarm is raised and the board is taken out of service.
g. The station went off-hook while it was in the ready-for-service state. Use
the status station command to determine the state of the station. The
off-hook should have moved the station to ready-for-service. No technician
action is necessary.
h. No terminal is connected to the Digital Line board. No maintenance action
is required.
i. The circuit pack's message buffer is full. This may be caused by having
many display phones with heavy traffic connected to the circuit pack. No
action is necessary.
j. Internal system error; no action is necessary. The error counters 1, 2, 3, 4,
5, 6, 10, 11, 12, 13, 14, 15, and 16 do not have any significance for this
MO.
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the table below when inspecting
errors in the system. For example, by clearing error codes associated with the
Voice and Control Channel Local Loop Around test (#13), you may also clear
errors generated from other tests in the testing sequence.
Order of Investigation
Voice and Control Channel Local Loop Around test (#13)
NPE Crosstalk test (#9)
Station Lamp Updates test (#16)
1.
D = Destructive; ND = Nondestructive
8-728
Issue 1 May 2002
Short Test
Long Test
Sequence
Sequence
X
X
X
555-233-143
1
D/ND
D
ND
ND